WEBR
With our expert façade solutions, your property will boast a refined, modern exterior that enhances curb appeal and makes a lasting impression on visitors, clients, and passersby.
Weber.Therm XM & XP External Wall Insulation System
The Weber.Therm XM & XP systems by Saint-Gobain Weber are high-performance external wall insulation (EWI) solutions designed for concrete and masonry buildings up to six storeys. The systems provide improved thermal efficiency, fire safety, and weather protection using a combination of high-quality insulation boards, reinforced render layers, and durable decorative finishes. They are fully compliant with Irish Building Regulations and come with a 10-year materials and workmanship guarantee, offering a service life expectancy of over 30 years when properly installed and maintained.
Use:
External insulation for new and existing concrete or masonry buildings up to 6 storeys (18 m) in height.
Not assessed for use with timber or steel frame structures.
System Components:
Substrate preparation (cleaning, priming, and repairs)
Adhesive and/or mechanical fixings
Insulation boards: EPS (white or graphite), Mineral Wool, Phenolic (PHS), PIR
Basecoat: Cementitious with glass-fibre mesh reinforcement
Topcoat/Finish: Primer and decorative finish (synthetic, silicone, dry-dash, brick, or textured)
Alternative system: Polymer-modified one-coat render (XP)
Weather seals, beads, movement joints, and fire stops
Compliance:
Complies with Irish Building Regulations 1997 and subsequent revisions (Parts A–L):
Part A: Structure – adequate strength and stability
Part B: Fire Safety – Class O / B-s1,d0; mineral wool systems are non-combustible
Part C: Weather and moisture resistance
Part D: Materials and workmanship
Part L: Conservation of fuel and energy
Fixings (typical):
EPS (adhesive + mechanical): minimum 2 supplementary + 1 stainless-steel fire fixing per m²
Mechanically fixed (EPS, Mineral Wool, Phenolic, PIR): minimum 5 fixings per board (≈7/m²) + 1 stainless-steel fire fixing per m²
Fire fixings not required in two-storey single occupancy dwellings
Positive fixings required around all window and door openings
Guarantee:
10-year materials and workmanship guarantee from Saint-Gobain Weber Ltd., subject to approved installation and maintenance.
Installation:
Designed and specified by Weber for each project, including U-value and fixing design
Installation must be carried out by Weber-trained and NSAI-approved contractors
Apply between 5 °C and 30 °C; avoid freezing or rapid drying conditions
Fire stops, movement joints, and weather seals must follow Weber’s approved details
Design life: minimum 30 years, with regular maintenance and inspections